Single ventilated improved pit vip sswm find tools. Ventilated improved pit latrines, research report series, department of civil engineering, university of leeds, england forthcoming. A pit latrine is a simple and inexpensive toilet, minimally defined as a hole pit in the ground. A case of blair ventilated improved pit latrines in matetsi ward, hwange district, international journal of academic research in business and social sciences, human resource management academic research society, international journal of academic research in business and social. Latrine design and construction making culturallyappropriate latrines. However, its conventional technical design fails to address the needs and preferences of some users. Tn07 tybasd 1om workshops for evaluating and planning sanitation programs. Manual removal of the humuslike material in the pits, which is at. The ventilated improved pit latrine is an improvement on standard pit latrines that eliminates flies and odour. Dear practical action, thank you for allowing me to download the vip latrine pdf. Pdf problems associated with the use of pit latrines in.
It comprises a stable foundation and flooring, a dark and sealed pit, and a ventilated pipe extending at least half a meter above the roof of the latrine, fitted with a fly screen. The design of ventilated improved pit latrines english. In study session 19, we described the various methods of liquid waste management and discussed the issues that need to be considered when choosing appropriate sanitation technologies. There are a number of designs to suit different situations but they all work in much the same way.
Apr 17, 2014 any other flush or pourflush latrine, an open pit latrine, bucket latrine, a hanging latrine, or open defecation is unimproved and not scored toward the mdg target. The design concept for this project consists of two key features. See guide 27 for more information about vip latrines. This has now been improved, with even greater success, as peter morgan and ephraim chimbunde report. Innovative approach for the management of faecal sludge. Ventilated improved pit vip toilet systems installed in south africa are constructed according to a wide variety of designs and with many different types of materials, with a corresponding. Significantly, public and other shared facilitiesthose used by two or more householdsare excluded from the definition of improved sanitation regardless of. One modification to the basic pit latrine is the ventilated improved pit latrine, or vip latrine. If the soil of the ground is very loose, it is recommended to use a lighter materials for the walls. The design of ventilated improved pit latrines pseau. This improved version, from which its name is derived, was designed to find a solution to, or at least reduce, this problem. Introduction to low cost sanitation 7 a b materials concrete stage a obtain tools and materials a good set of tools is needed to easily and properly excavate and line a pit, build a mold, and pour a slab.
It essentially involves providing the inside of the latrine with a vertical ventilation pipe, referred to as a vent, the top of which is fitted with a finemesh insect screen. The addition of a chimney draws air currents into the structure and through squat hole. Factors contributing to low sanitation and hygiene coverage. Ventilated improved pit vip latrine this is a row of double vip latrines for a school in lesotho in southern africa. A latrine was constructed in the nonwash groups following trial completion. Independent and combined effects of improved water. We tested the independent and combined effects of improved water, sanitation, and hygiene wash, and improved infant and young child feeding iycf on stunting and anaemia in in zimbabwe.
Two techniques controlling lmproved ventilated pit. It is a 4mb pdf file but is a must for groups that have never built before or maybe he has a shot of. Many military units, if intended for extended use, place basic shelters and seating over the pits. Pit latrine operational management and sludge accumulation rate, presents a challenging sanitation problem in lowincome urban settlements. The vip latrine was developed to overcome the problems of odour and fly breeding commonly found in unvented pit latrines. The work in botswana was funded by the united kingdom science and engineering research council, and that in zimbabwe by tag. Even though the factors affecting the ventilation rate have been well researched, they have not been previously related in a mathematical model to quantify the relative effect. December 1, 2004 downloads pdf available on line at. This discussion paper provides guidelines that will enable a design engineer to make a rational selection of the vip latrine design option most appropriate to the community for which he is responsible. This study was carried out between december 2014 and september 2015 in nakuru, kenya. Design and construction of household ventilated improved.
The design of ventilated improved pit latrines excretarelated diseases are responsible for a large proportion of the morbidity and mortality in developing countries, especially amongst lowincome communities in urban fringe and rural areas, where adequate water supplies and sanitation facilities. Also available casa house plans casita plans special thanks to hector rubio for his service and help in creating these plans. Own ership of property, poverty and theft in the area significantly influenced the type and structural condition of the latrine. These should be chosen according to availability and cost of materials, skills available, and soil type. There are a number of designs to suit different situations but they all work in much the. Excretarelated diseases are responsible for a large proportion of the morbidity and mortality in developing countries, especially amongst lowincome communities in urban fringe and rural areas, where adequate water supplies and sanitation facilities. Latrine design and construction part 1 humanitarian response. They use similar technology, the main difference being that the pit of the roec is wholly offset from the slab and connected to it by achute. In ghana, only 14% of the population have access to improved. Pdf redesigning the ventilated improved pit latrine for use. The designer is aiming at a technical choice that will be affordable to the householder and will give the best longterm service at the least cost. Oct 11, 2018 the rate of ventilation through the vent pipe of a ventilated improved pit latrine is the main technical factor that determines its efficiency in odour control aside the maintenance and cleaning practices of the users. Vip latrines are an improvement to overcome the disadvantages of simple pit latrines, e.
The robbins building, 25 albert street, rugby, warwickshire cv21 2sd, united kingdom. The ventilated improved pit vip latrine is now widely recognized as one of the most important, affordable and appropriate onsite sanitaion technologies for use in both urban and rural areas of developing countr es. Even though the factors affecting the ventilation rate have been well researched, they have not been previously related in a mathematical model to. Access to improved sanitation facilities is critical to the health and wellbeing of individuals and communities. The ventilated improved pit latrine was the commonest technology used by 47 % of. Tables 1 and 2 present the main results from rural and urban areas for traditional pit latrines tpls and ventilated improved. Ventilated improved pit vip latrines loughborough university. However, the provision of appropriate sanitation service in the form of vip latrines to all goes beyond building the toilets, plans should be put in place by municipalities are for adequate operation and maintenance of the. The ventilated improved pit vip latrine has the potential to address the challenge of access to improved sanitation in builtup lowincome settings. This type of latrine is called a ventilated improved pit vip latrine. Pdf design and construction of household ventilated. Ventilated improved pit vip latrines moi ot 3 introduction the addition of a vent pipe to a simple pit latrine is one way of reducing the nuisance of flies in the cubicle if the cubicle is kept clean and dark. Pdf redesigning the ventilated improved pit latrine for use in built. Optimising ventilation to control odour in the ventilated.
Vip latrines effectively control odour and flies while still allowing users to clean themselves with hard materials such as newspaper and leaves which may not suitable for. Ventilated improved pit vip latrine design for guatemala. The distinctive feature that gives the vip latrine its name is the vent pipe installed into the pit, which is used to exhaust the foul odour from the pit and control flies figure 20. Are pit latrines in urban areas of subsaharan africa. The design of ventilated improved pit latrines english abstract.
The ventilated improved pit latrine or vip latrine differs from a standard improved latrine due to the addition of a vent pipe figure 5. All you need are hand tools, which will provide you with many years of useful life if they are properly maintained, handled and stored. However, greater care has to be taken when digging and lining the pit because of its. The vip latrine is an improvement over the simple dry pit latrine. The base and superstructure can then be moved and used again. Wash construction of a ventilated improved pit latrine, provision of two handwashing stations. This work is licensed under a creative commons attribution 4. Ventilated improved pit latrines guidelines for the selection of design options. Additionally, a ventilated improved pit latrine was provided within 6 weeks of enrolment. Any other flush or pourflush latrine, an open pit latrine, bucket latrine, a hanging latrine, or open defecation is unimproved and not scored toward the mdg target.
The ventilated improved pit latrine was the commonest technology used by 47 % of households with private latrines. This latrine design will last 10 years for 4 people and 5 years for 8 people. It didnt work first time around because my firewall. Redesigning the ventilated improved pit latrine for use in. The preferred sanitation technology in swaziland is the ventilated improved pit latrine vip. Redesigning the ventilated improved pit latrine for use in builtup lowincome settings. All other design considerations are covered in the simple pit latrine sheet s. This is for safety when digging the pit and to support the cement base and superstructure on top of the cement base. The addition of a vent pipe to a simple pit latrine is one way of reducing the nuisance of flies in the cubicle if the cubicle is kept clean and dark. So building and using a latrine any type at all is the most important step to take. Five households used ventilated improved latrines whilst the remaining eight per cent made use of their neighbours latrine. A case study of priimay schools sanitation in lesotho. Ventilated improved pit latrine introduction the ventilated improved pit v.
Preparation of standard engineering drawings, specifications and guidelines for ventilated improved pit latrines in south africa. A practical guide for building a simple pit latrine sue. P latrine offers improved sanitation by eliminating flies and smell, through air circulation. Environmental improvements such as the provision of latrines for schools help to remove human faeces from the environment. Wall slab ventilation roof frame soap water tank pit any type of improved latrine that breaks the contact between feces and the environment will be of bene. Improved sanitation is a term used to categorize types or levels of sanitation for monitoring purposes. Latrine costs in burkina faso anuary 2012 6 main findings the costs presented here were obtained from a sample of six villages and three urban sectors in three regions. Problems associated with the use of pit latrines in. Latrine design and construction lifewater international. Further details of countryspecific deslgns currently for botswana, tanzania and zimbabwe are given in other technical notes in this series. The vip latrine is a pit latrine with a vent pipe fitted to the pit and a screen at the top outlet of the pipe. This technical brief concentrates on the ventilated improved pit latrine construction the vip latrine can be built from different materials. These include wet sanitation technologies flush and pour flush toilets connecting to sewers, septic tanks or pit latrines and dry sanitation technologies ventilated improved pit latrines.
The design of ventilated improved pit latrines english the world. This study was conducted to identify the gaps that exist between ventilated improved pit vip latrine construction practices in cape coast, ghana, and conventional technical guidelines, and to assess how any noncompliance with technical guidelines influences the users perception of odour and fly nuisances. Learning brief what can be done when latrines become full. Ventilated improved pit latrine simon farmer practical answers. The upscaling and delivering of sanitation in many cases in the form of vips and its derivatives, as well as urine diversion technology are beginning to pose many technical challenges. More sophisticated pit latrines may include a floor plate, or ventilation to reduce odor and fly and mosquito breeding called ventilated improved pit latrine or vip latrine. Improved sanitation facilities are those designed to hygienically separate excreta from human contact, and include.
Design and construction of household ventilated improved pit. This approach focuses on creating a durable substructure i. Pdf on mar 14, 2018, babatunde femi bakare and others published scientific support for the design and operation of ventilated improved pit latrines and the efficacy of pit latrine additives. It didnt work first time around because my firewall blocked the download.
Problems associated with the use of pit latrines in blantyre. Its objectives were to determine pit latrine management activities and content accumulation rates. Pdf the ventilated improved pit vip latrine has the potential to address the challenge of access to improved. In spite of the wide spread use, known successes and advantages associated with pit latrines, they have received little attention in form of research and development. Ventilated improved pit latrines vip has been considered to be the minimum acceptable level of sanitation service. The vip latrine was developed to overcome the problems of odour and fly breeding commonly found in.
The term was coined by the joint monitoring program jmp for water supply and sanitation of unicef and who in 2002 to help monitor the progress towards goal number 7 of the millennium development goals mdgs. Ventilated improved pit latrine simon farmer practical. The rate of ventilation through the vent pipe of a ventilated improved pit latrine is the main technical factor that determines its efficiency in odour control aside the maintenance and cleaning practices of the users. Ventilated improved pit vip latrines resources susana. The only design difference to a single pit latrine is the ventilation. This study assessed how users of ventilated improved pit vip latrines in cape coast, ghana, perceive the level of odor in their latrines and identified the factors associated with perception of bad odor. Improved sanitation facilities latrine are those designed to hygienically separate excreta from human contact. The ventilated improved pit latrine vip is a pit latrine with a black pipe vent pipe fitted to the pit and a screen flyscreen at the top outlet of the pipe.
Factors associated with perception of bad odor by users of. Information on improved latrine options 11 part 3 what do we mean by latrine. Introduction dear builder, the purpose of this manual is to explain how a ventilated improved pit v. Zimbabwean brick designs this paper describes the most recent developments in the design of ventilated improved pit vip latrines in zimbabwe. Note the screened pipes which prevent flies from entering or being able to escape from the latrines. A pit latrine is the most basic form of improved sanitation which is currently used by a number of people around the globe. For the ventilation, a straight vent pipe is needed with an internal diameter of at least 11 cm and reaching more than 30 cm above the highest point of the toilet superstructure. To improve safe access to sanitation it is necessary to. Shared sanitation versus individual household latrines. Ventilated improved pit latrines bellatrines portable vip.
Ventilated improved pit vip and reeds odourless earth closet roec latrines these are both improved types of pit latrine which aim to remove smells and flies from the latrine using a vent pipe. It seeks to clarify the current state of ventilated improved pit latrine design, which often includes a bewildering set of design options such as single or twin pits, emptiable or nonemptiable, lined or unlined and raised above ground level or unraised. Globally, linear growth faltering ie, stunting is the most prevalent form of undernutrition. Download statistics measured since january 1st, 2014. Ventilated improved pit latrine 209 arborloo latrine. Pdf scientific support for the design and operation of. This technical note sets out preliminary guidelines for the design and construction of vent pipes for ventilated improved pit vip latrines. This paper describes the most recent developments in the design of ventilated improved pit vip latrines in zimbabwe. The pit latrine technology currently offers a number of options ranging from simple designs like the traditional without concrete slabs to the simple improved, and further to more advanced ventilated improved vip, reed odourless earth closet roec, pour flush and borehole pit latrines. A practical guide for building a simple pit latrine. Download a simple printable individual checklist casa waiver form. Latrine construction study session 20 latrine construction introduction. Location if a latrine has direct access from the house there is a greater likelihood that it will be properly maintained.
890 794 365 944 1125 44 1018 1063 1458 372 1070 1529 387 1343 644 227 430 83 48 311 648 98 1361 84 640 1265 730 1291 1181 692